Hello,
Try running the command "hw-module module 7 reset"
you may want to call Cisco TAC if that doesn't work
On Wed, Mar 3, 2010 at 8:39 AM, Fake Name <fname84_at_gmail.com> wrote:
> We poped a new line card into the 6509 and it wont come up any assistance
> would be great.
>
>
>
> 6509Switch#show module 7
> Mod Ports Card Type Model Serial
> No.
> --- ----- -------------------------------------- ------------------
> -----------
> 7 24 CEF720 24 port 1000mb SFP WS-X6724-SFP
> SAL135069ZC
>
> Mod MAC addresses Hw Fw Sw
> Status
> --- ---------------------------------- ------ ------------ ------------
> -------
> 7 c47d.4fb9.8a88 to c47d.4fb9.8a9f 4.3 Unknown Unknown
> PwrDown
>
> Mod Sub-Module Model Serial Hw
> Status
> ---- --------------------------- ------------------ ----------- -------
> -------
> 7 Centralized Forwarding Card WS-F6700-CFC SAL13516G9F 4.1
> PwrDown
> Mod Online Diag Status
> ---- -------------------
> 7 Not Applicable
>
> 6509Switch#show power status module 7
> Pwr-Requested Pwr-Allocated Admin Oper
> Slot Card-Type Watts A @42V Watts A @42V State State
> ---- ------------------ ------- ------ ------- ------ ----- -----
> 7 WS-X6724-SFP 125.16 2.98 - - on off (Fabric
> required)
>
> 6509Switch#show power
> system power redundancy mode = redundant
> system power redundancy operationally = non-redundant
> system power total = 1171.38 Watts (27.89 Amps @ 42V)
> system power used = 704.34 Watts (16.77 Amps @ 42V)
> system power available = 467.04 Watts (11.12 Amps @ 42V)
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>
-- -Steve Di Bias Blogs and organic groups at http://www.ccie.netReceived on Wed Mar 03 2010 - 09:28:09 ART