Re: 4507-Dual SUP- UPLink on both SUP-Redundancy

From: S Malik <ccie.09_at_gmail.com>
Date: Wed, 30 Dec 2009 13:32:47 -0500

If you have two uplinks, one link from Active Sup goes to a switch (say root
for odd # vlans) and second link from Standby Sup to a switch which is root
for even # of vlans, then both links should be in forwarding mode, Link from
Active sup should be in forwarding mode for Odd vlans and link from Standby
Sup should be in forwarding mode for Even numbered vlans.

On Wed, Dec 30, 2009 at 5:51 AM, jack daniels <jckdaniels12_at_gmail.com>wrote:

> Hi All,
>
> On 4507 switch , if we have two upliunks coming on two SUP ( 1 active other
> standby). Now what I know is link will come up only on active sup. If link
> on active sup goes down (ACTIVE SUP STILL UP), how to achieve redundancy
> from link on standby sup.
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net
Received on Wed Dec 30 2009 - 13:32:47 ART