Re: 4507-Dual SUP- UPLink on both SUP-Redundancy

From: jack daniels <jckdaniels12_at_gmail.com>
Date: Wed, 30 Dec 2009 17:50:36 +0530

But is there some way out of redundancy of uplinks if standby sup interface
is not operational till ACTIVE sup is down

On Wed, Dec 30, 2009 at 5:15 PM, Danshtr <danshtr_at_gmail.com> wrote:

> I have tested 4507 with two SUP-6e.
>
> Both interfaces on both SUPs are fully operational, regardless of the SUP
> standby state.
>
> Best regards,
> Dan #13685 (RS/Sec/SP)
> CCIE Troubleshooting blog: http://dans-net.com
>
>
> On Wed, Dec 30, 2009 at 12:51 PM, jack daniels <jckdaniels12_at_gmail.com>wrote:
>
>> Hi All,
>>
>> On 4507 switch , if we have two upliunks coming on two SUP ( 1 active
>> other
>> standby). Now what I know is link will come up only on active sup. If link
>> on active sup goes down (ACTIVE SUP STILL UP), how to achieve redundancy
>> from link on standby sup.
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net