Re: 4507-Dual SUP- UPLink on both SUP-Redundancy

From: Danshtr <danshtr_at_gmail.com>
Date: Wed, 30 Dec 2009 13:45:43 +0200

I have tested 4507 with two SUP-6e.

Both interfaces on both SUPs are fully operational, regardless of the SUP
standby state.

Best regards,
Dan #13685 (RS/Sec/SP)
CCIE Troubleshooting blog: http://dans-net.com

On Wed, Dec 30, 2009 at 12:51 PM, jack daniels <jckdaniels12_at_gmail.com>wrote:

> Hi All,
>
> On 4507 switch , if we have two upliunks coming on two SUP ( 1 active other
> standby). Now what I know is link will come up only on active sup. If link
> on active sup goes down (ACTIVE SUP STILL UP), how to achieve redundancy
> from link on standby sup.
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net
Received on Wed Dec 30 2009 - 13:45:43 ART

This archive was generated by hypermail 2.2.0 : Sat Jan 02 2010 - 11:11:08 ART