Re: 4507-Dual SUP- UPLink on both SUP-Redundancy

From: Matt Martin <m.mattymat_at_gmail.com>
Date: Thu, 31 Dec 2009 00:11:59 +1300

Hi,

I think the redundancy is already configured for you when the standby is
discovered.

should be something like

redundancy
mode rpr
main-cpu
auto-sync standard

I think this is default.

On Wed, Dec 30, 2009 at 11:51 PM, jack daniels <jckdaniels12_at_gmail.com>wrote:

> Hi All,
>
> On 4507 switch , if we have two upliunks coming on two SUP ( 1 active other
> standby). Now what I know is link will come up only on active sup. If link
> on active sup goes down (ACTIVE SUP STILL UP), how to achieve redundancy
> from link on standby sup.
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net
Received on Thu Dec 31 2009 - 00:11:59 ART

This archive was generated by hypermail 2.2.0 : Sat Jan 02 2010 - 11:11:08 ART