They will accomplish the same thing , the second config will restrict
the traps sent to the management station to just the ones specified in
the snmp-server command . This prevents the sending of all traps in
case other ones have been enabled
On 10/2/09, Adrian <ccie2323_at_gmail.com> wrote:
> Hi Experts,
> I'm abit confused with regards configuration of snmp traps.
> I would like to know the difference between the below 2.
>
> *Configuration 1*
> snmp-server enable traps mac-notification
> snmp-server enable traps snmp linkup linkdown
> snmp-server host 172.16.1.61 traps version 2c public
>
> *Configuration 2*
> snmp-server enable traps mac-notification
> snmp-server enable traps snmp linkup linkdown
> snmp-server host 172.16.1.61 traps version 2c public mac-notification snmp
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>
-- Warm Regards , Usain TheThunderbolt CCNAX3 (Voice , Security , Wireless ) Blogs and organic groups at http://www.ccie.netReceived on Fri Oct 02 2009 - 21:32:23 ART