Sagar,
When the tracked object event goes, it should produce a log entry. Use the syslog event matching to trigger your EEM.
-ryan
-----Original Message-----
From: nobody_at_groupstudy.com [mailto:nobody_at_groupstudy.com] On Behalf Of Sagar Rane
Sent: Tuesday, September 15, 2009 3:29 AM
To: Cisco certification
Subject: Track object going down to trigger EEM
Dear All,
I am using track to detect a particular condition and it goes down when that
condition is not met.
Once this happens I want to use EEM to execute certain commands.
Now I am restricted to a IOS version that only has the following event under
event manager config.
application Application specific event
cli CLI event
counter Counter event
interface Interface event
ioswdsysmon IOS WDSysMon event
none Manually run policy event
oir OIR event
snmp SNMP event
syslog Syslog event
timer Timer event
How can I use track object going down as a trigger for EMM. Please provide
any ideas on this.
Regards,
sagar.ccie
Blogs and organic groups at http://www.ccie.net
Received on Tue Sep 15 2009 - 08:51:36 ART