AW: AW: VSS and PFC3A

From: KRATTIGER Lukas <Lukas.KRATTIGER_at_nextiraone.ch>
Date: Tue, 4 Aug 2009 16:51:15 +0200

Hi Ram

You are correct. The DFC, CFC are on the linecards. There are also
limitations according to the daughter cards.

The only VSS compatible Supervisor is the VS-S720-10GE-3C/XL. It's a
Sup720 with 2x 10G and PFC3c on it. All other Sups are not able to do
VSS.

I hope this helps.

Cheers

-Lukas

Von: Ram Shummoogum [mailto:rshummoo_at_ca.ibm.com]
Gesendet: Dienstag, 4. August 2009 16:44
An: KRATTIGER Lukas
Cc: ccielab_at_groupstudy.com
Betreff: Re: AW: VSS and PFC3A

Thanks for getting back so fast.

When you say remove the PFC3A and replace with CFC or DFC3c/DFC3cXL: Are
you referring to the SUP720. I thought CFC and DFC are only for
linecards.

For the line cards I am good as they are new and are DFC3C.

Thanks

"KRATTIGER Lukas" <Lukas.KRATTIGER_at_nextiraone.ch>

08/04/2009 10:38 AM

To

Ram Shummoogum/Quebec/IBM_at_IBMCA, <ccielab_at_groupstudy.com>

cc

Subject

AW: VSS and PFC3A

Hi Ram

Just remove your PFC3A and replace it with a CFC or buy a DFC3c/DFC3cXL.
These are your two options.
A VSS will never work with distributed forwarding below 3c.
Just as a side note: The linecards for your VSLs need to have a
DFC3c/DFC3cXL on it.

Cheers
-Lukas

Blogs and organic groups at http://www.ccie.net
Received on Tue Aug 04 2009 - 16:51:15 ART