Hi Sajjad,
I am going to need a bit more information from each router, such as:
    * show controller SLOT/PORT
    * show interface SLOT/PORT
Some simple things to consider, E1 RJ45 is not the same as Ethernet 
RJ45, the pin outs are different. Now this does not make a difference 
when you are connecting to a provider and can use a straight through 
cable. It does present itself, however when you back to back E1 cards 
you need to put a cross in the TX and RX pairs - which is not the same 
as a crossover Ethernet cable. The other simple thing is clocking, one 
end will need to generate the clock, and the other set to receive the 
clock from line. As they are T1/E1 modules, you will also need to select 
the mode of operation - this is performed under global configuration mode.
regards Andy
Sajjad Najafizadeh wrote:
> Hi All
>
> I have 2 router with this config :
>
> 1-2821 with VWIC-2MFT-1/E1
> 2-7206 VXR with PA-MC-8TE1 +
>
> Both routers have E1 module with RJ45 interfaces ( Not serial DCE/DTE )
> cable.
> The issue is i can not bring up the serial interface even controller E1 that
> is directly connected from one router to another.
>
> Please help .
>
> Regards
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at: 
> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net
Received on Tue Jul 21 2009 - 21:22:30 ART
This archive was generated by hypermail 2.2.0 : Sat Aug 01 2009 - 13:10:22 ART