Hi,
you are correct. By enabling snmp-server enable traps, link up/down message
is sent to syslog server.
If the link is of fluctuating type like dial up connection it is better to
disable this trap by using command "no snmp trap link-status".
Hope it helps you
R.B.KUMAR
2009/6/3 nowy1981 <freemaxis_at_gmail.com>
> What is prefer way to enable traps regarding interface up/down transition.
>
> I understand that for Ethernet interfaces its: snmp-server enable traps
> snmp linkup linkdown and by default it enables for all interface (does it
> enable for FR interfaces type?)
>
> For FR it's:
>
> snmp-server enable traps frame-relay
> snmp-server enable traps frame-relay subif
>
> If we would disable for specifi interfaces, we have to use following:
>
> interface FastEthernet0/0
> no snmp trap link-status
>
> Am I right?
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net
Received on Wed Jun 03 2009 - 19:46:40 ART
This archive was generated by hypermail 2.2.0 : Wed Jul 01 2009 - 20:02:36 ART