IP Interface Dampening

From: Divin Mathew John <divinjohn_at_gmail.com>
Date: Fri, 1 May 2009 01:33:48 +0530

"Maximum Suppress Time

The maximum suppress time represents the maximum amount of time an
interface can remain dampened when a penalty is assigned to an
interface. The maximum suppress time can be configured from 1 to 20000
seconds. The default of the maximum penalty timer is 20 seconds or
four times the default half-life period (5 seconds). The maximum value
of the accumulated penalty is calculated, based on the maximum
suppress time, reuse threshold, and half-life period. "

Does the above excerpt from the DOC Cd mean...that after Max Suppress
time (default:20secs) ... whtever the penalty is... and even if the
interface is Unstable aftyer 20 seconds it will be unsupressed. if
yes... wht happens to the penalty? is it reset to 0?

Thanking You

Yours Sincerely

Divin Mathew John
divinjohn_at_gmail.com
divin_at_dide3d.com
http://www.dide3d.com
+91 9945430983
+91 9846697191
+974 5008916
PGP PUBLIC KEY BLOCK @ http://www.dide3d.com/divin_Public_PGP_key.txt
Sent from Bangalore, KA, India

Blogs and organic groups at http://www.ccie.net
Received on Fri May 01 2009 - 01:33:48 ART

This archive was generated by hypermail 2.2.0 : Mon May 04 2009 - 07:39:13 ART