RP/MA placement issues in FR HnS

From: Naveen <navin.ms_at_gmail.com>
Date: Sat, 11 Apr 2009 16:03:18 -0800

Group,

After working through several exercises, I have made this little notes about
RP and MA placements. From your experience, if something is not correct, plz
suggest.

R1 and R3 are spokes. R5 is Hub of FrameRelay.
R1 and R3 uses p2p serial ub-interface. R5 uses Main serial interface.

-------------------------------------------------------------------------------------------------
Item Mode RP MA Auto-RP works? Solution
-------------------------------------------------------------------------------------------------
1. Sparse-Dense R5 R5 Yes
2. Sparse-Dense R1/R3 R5 Yes
3. Sparse-Dense Any R1/R3 No GRE Tunnel
b/n R1 & R3

--------------------------------------------------------------------------------------------------
Item Mode RP Source Client Mcast works? Solution
-----------------------------------------------------------------------------------------------
4. Sparse R5 R1 R3 No ip pim
nbma-mode on R5

--------------------------------------------------------------------------------------------------
Item Mode RP Source Client Mcast works? Solution
-----------------------------------------------------------------------------------------------
5. Dense R5 R1 R3 No GRE
Tunnel b/n R1 & R3 (??)

Thanks,
Naveen.

Blogs and organic groups at http://www.ccie.net
Received on Sat Apr 11 2009 - 16:03:18 ART