Re: HELP!!!!! auto-cost reference-bandwidth

From: Wouter Prins <wp_at_null0.nl>
Date: Sat, 4 Apr 2009 13:55:54 +0200

The auto-cost reference should be specified in M. So your answer is fine
when you do the math, but the configuration is different.

The math:

Metric = Reference/BW of interface
5 = Reference/1000000000
Reference = 5000000000

To get to the M value: 5000000000/10^6 = 5000

2009/4/4 ftt <femi0802_at_googlemail.com>

> Question => What value should you enter for the ref-bw parameter in the
> auto-cost command to configure a 1gig link to be a cost of 5 ?
>
> My answer is 5000000
>
> But solution says 5000
>
> Can you help explain this?
>
>
> Blogs and organic groups at http://www.ccie.net
>