RE: Serial0/0 is up, line protocol is down

From: Scott Morris (smorris@internetworkexpert.com)
Date: Sat Mar 07 2009 - 11:13:12 ARST


The timing seems off to me (20 seconds between up/down). I would expect 30
seconds if the keepalives were not working.

Check "show interface s0/0 | in Keep"

And you may also want to do a "debug serial interface" on both sides. Make
sure timestamps are on for your debugs as well, but watch the keepalives go
back and forth.

It's possible to be a physical thing as well. Perhaps a pin is bent or
something?

Scott Morris, CCIE4 #4713, JNCIE-M #153, JNCIS-ER, CISSP, et al.
JNCI-M/JNCI-ER
Senior CCIE Instructor

smorris@internetworkexpert.com
 

Internetwork Expert, Inc.
http://www.InternetworkExpert.com
Toll Free: 877-224-8987
Outside US: 775-826-4344

Knowledge is power.
Power corrupts.
Study hard and be Eeeeviiiil......

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Xiaobo Zhu
Sent: Saturday, March 07, 2009 6:41 AM
To: CCIE Lab
Subject: Re: Serial0/0 is up, line protocol is down

Here is the notification

R1(config-if)#
*Mar 1 00:03:14.983: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0/0, changed state to up
R1(config-if)#
*Mar 1 00:03:34.984: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0/0, changed state to down
R1(config-if)#
*Mar 1 00:03:44.984: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0/0, changed state to up
R1(config-if)#
*Mar 1 00:04:04.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0/0, changed state to down
R1(config-if)#
*Mar 1 00:04:14.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0/0, changed state to up
R1(config-if)#
*Mar 1 00:04:34.986: %LINEPROTO-5-UPDOWN: Line protocol on Interface
Serial0/0, changed state to down
R1(config-if)#