From: Alexei Monastyrnyi (alexeim73@gmail.com)
Date: Mon Dec 22 2008 - 07:43:05 ARST
second this, we had that before with 0x1 confreg on a slave 720 after
some time, didn't really notice whan it turned to this, found it hard
way when got no cigar after power cut :-)
A.
Pavel Bykov wrote:
> Agree with Dale.
> I have seen this mishap with config ragister a lot, when it is set to
> something like 0x1
> Set it to standard autoboot and you should be good to go
>
> On Wed, Dec 17, 2008 at 3:16 AM, Dale Shaw <dale.shaw@gmail.com> wrote:
>
>
>> Hi Jeffrey,
>>
>> On Wed, Dec 17, 2008 at 11:58 AM, Jeffrey Biggs <j.biggs@myactv.net>
>> wrote:
>>
>>> Trying to setup SUP720's redundant in a 6509 chassis and need some good
>>> documentation to find out why the chassis boots into rommon until I tell
>>>
>> it
>>
>>> to "boot" then the IOS takes off and the RP then boots. I have my
>>> "theories" but they are nothing more than that as it is hard to find a
>>>
>> good
>>
>>> link to some documentation on setting this up.
>>>
>> I've seen this happen when the SP has the wrong config-register.
>>
>> Once the RP is booted, login and run:
>>
>> "remote command switch show boot"
>>
>> If it's something other than 0x2102, or some other value that means
>> it'll go into ROMMON, just re-enter the config-register in the RP and
>> write the config -- the proper value will be propagated to the SP
>> (verify with the same command as above).
>>
>> cheers,
>> Dale
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net