RE: 3750 and power inlnie

From: Geert Nijs (Geert.Nijs@simac.be)
Date: Thu May 29 2008 - 06:45:55 ART


Its a power controller failure. The post says:

POST: Inline Power Controller Tests : Begin
POST: Found inline power controller write failure, inst 0
POST: Inline Power Controller Tests : End, Status Failed
POST: Inline Power feature is disabled on this switch

This happened on a remote site after a thunderstorm.

Geert

________________________________
From: A.G. Ananth Sarma (GMail) [ananth.sarma@gmail.com]
Sent: 28 May 2008 11:35
To: Geert Nijs
Cc: ccielab@groupstudy.com
Subject: Re: 3750 and power inlnie

Hi Geert,

I had a similar issue on 3560 PoE switches where the 25th phone does not get the power.

This is due to the fact that the power available on the switch was 370 W and by default, each port is allocated 15.4 W.
(370 / 15.4 = 24.026 phones max).

As per one of the Voice Experts in the GS, I tweaked the power on the switch ports to 6.3W ( IP Phone 7941) and 5.0 W ( IP Phone 7911) and so on. By this way, I managed to utilise more or less all the ports.
( IP Phone 7971 should also work with 6.3 W which I do not remember exactly).
To do this, go to the interface config mode and run : power inline consumption 6300

You may get a warning, but that is ok to ignore. Better shutdown the port before apply this command.

I know what I have written above may not be fully relevant to your case, but may be handy for later usage.

Try shutting down the ports and enable / Or reload the 4th switch during non-production hours.

Let us know as to how you fix this.

Regards,

Ananth

On Wed, May 28, 2008 at 11:43 AM, Geert Nijs <Geert.Nijs@simac.be<mailto:Geert.Nijs@simac.be>> wrote:
Hi group,

Is it possible for a 3750 to fail completely regarding PoE, but keep functioning normally for the rest ?
Are all PoE-functions controlled by one critical "power controller" maybe ?
I have a PoE-capable switch, where suddenly the available power has dropped to 0 and not a single port gets powered....

sh power inline
Module Available Used Remaining
         (Watts) (Watts) (Watts)
------ --------- -------- ---------
1 370.0 170.1 199.9
2 370.0 155.6 214.4
3 370.0 187.1 182.9
4 n/a n/a n/a <<<<<<<-------- ??????????????

Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 52 WS-C3750-48P 12.2(25)SED1 C3750-IPBASE-M
    2 52 WS-C3750-48P 12.2(25)SED1 C3750-IPBASE-M
    3 52 WS-C3750-48P 12.2(25)SED1 C3750-IPBASE-M
    4 52 WS-C3750-48P 12.2(25)SED1 C3750-IPBASE-M <<<--- power enabled.

regards,
Geert

________________________________
disclaimer : http://webservices.simac.be/disclaimer.htm



This archive was generated by hypermail 2.1.4 : Mon Jun 02 2008 - 06:59:18 ART