From: V.Shekhar@GlobalAssurance.net
Date: Fri May 02 2008 - 14:15:45 ART
Consider a scenario
R1---R2---R3--vlan3
Link R1--R2 is in OSPF area 12
link R2 --R3 is in OSPF area 23
VLAN3 on R3 is in area 0
Loopback int on R1 R2 and R3 are in area 0.
Now to connect dis contiguous area 0 i can have 2 possible solutions.
SOL1:
VL from R1 to R2 and VL form R2 to R3
SOL2:
VL form R1 to R3 and VL from R2 to R3.
I have seen in various WBs that they follow SOL1.
I have tested both solutions work. however thats the advantage of using
one over other? will I be peanilised for the solution I choose?
Thanks!
-V Shekhar
CCIE(sec)#17589/CISSP/RHCE.
Pass the CCIE in six weeks, Guaranteed!
http://www.certscience.com/CCIE
This archive was generated by hypermail 2.1.4 : Mon Jun 02 2008 - 06:59:15 ART