From: Rich Collins (nilsi2002@gmail.com)
Date: Thu Mar 20 2008 - 13:35:23 ART
This should work if you are tracking DLCI 104 on R1's S1/0.
ip sla monitor 1
type frame-Relay interface Serial1/0 dlci 104
timeout 1000
frequency 3
ip sla monitor schedule 1 life forever start-time now
track 2 rtr 1
R1#sh track 2
Track 2
Response Time Reporter 1 state
State is Up
1 change, last change 00:00:07
Latest operation return code: OK
Latest RTT (millisecs) 19
R1#
You need a responder on R4 - this tricked me up before.
R4#
rtr responder type frame-relay interface Serial1/0 dlci 401
(you might need to enter the above as "ip sla monitor responder ...)
-Rich
On 3/20/08, Sadiq Yakasai <sadiqtanko@gmail.com> wrote:
>
> Hi Nagendra,
>
> Whats the requirement of the quesion? Are you to track R1's
> connectivity to R4 or R2 or are you just checking the physical status
> of the FR interface on R1?
>
> I think this information would guide you as to what you should be
> really tracking there.
>
> Sadiq
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html