From: nhatphuc (nhatphuc@gmail.com)
Date: Wed Jan 02 2008 - 10:08:18 ARST
Thanks Shafagh.
I've found the problem. Below is how I did:
I created 2 interface tunnel between R1 and R4, they use the same tunnel
source and destination.
Now I change to different source/des pair and it works. Another solution is
combining them into 1 tunnel interface. The later is better, I think.
Regards,
Phuc
---------- Forwarded message ----------
From: Shafagh Zandi <szmetal@gmail.com>
Date: Jan 2, 2008 6:59 PM
Subject: Re: Interface tunnel down after reload
To: nhatphuc <nhatphuc@gmail.com>
Try to set keepalive and let see.
Shafagh Zandi
On Jan 2, 2008 3:41 PM, nhatphuc <nhatphuc@gmail.com> wrote:
> HI Group,
>
> I have a tunnel interface configured and tested successfully. After I
reboot
> all router, I can't ping tunnel interface address, if I delete the tunnel
> int and create it again. Everything works well.
>
> Have you ever experienced this ?
This archive was generated by hypermail 2.1.4 : Fri Feb 01 2008 - 10:37:57 ARST