From: shiran guez (shiranp3@gmail.com)
Date: Mon Dec 17 2007 - 02:56:39 ART
correction in my wording the ip route-cache flow is to activate the NetFlow
and it is not a Switching mode, the Switching mode is CEF in case you want
to work with NetFlow.
On Dec 17, 2007 7:53 AM, shiran guez <shiranp3@gmail.com> wrote:
> if I am not mistaken you cant collect the flows you can only send to the
> collector and to send you need to activate first the netflow switching mode
> with Ip route-cache flow
>
> and then put the
>
> Ip flow ingress
>
> Ip flow egress
> to send the flow to the collector:
>
> ip flow-export destination <ip of the collector> <port>
>
> On Dec 17, 2007 5:15 AM, PANDI MOORTHY <moorthypandi@gmail.com> wrote:
>
> > Hi Group,
> >
> >
> >
> > My task is to collect the netflow data for traffic coming in and out to
> > the
> > interface
> >
> >
> >
> > My answer:
> >
> >
> >
> > *Option 1:*
> >
> > Int ser 1/0
> >
> > Ip route-cache flow
> >
> >
> >
> >
> >
> > *Option 2*:
> >
> > Int ser 1/0
> >
> > Ip flow ingress
> >
> > Ip flow egress
> >
> >
> >
> > Could you please confirm both answers doing the same?
> >
> > I did some test, both options able to capture the data.
> >
> >
> > Regards
> > Pandi
> >
> > _______________________________________________________________________
> > Subscription information may be found at:
> > http://www.groupstudy.com/list/CCIELab.html
> >
>
>
>
> --
> Shiran Guez
> MCSE CCNP NCE1
> http://cciep3.blogspot.com
> http://www.linkedin.com/in/cciep3
-- Shiran Guez MCSE CCNP NCE1 http://cciep3.blogspot.com http://www.linkedin.com/in/cciep3
This archive was generated by hypermail 2.1.4 : Tue Jan 01 2008 - 12:04:31 ARST