From: Muhammad Saleem (msaleems@gmail.com)
Date: Fri Nov 09 2007 - 15:37:54 ART
I already have Smart Serial DCE Interface to DB60 DTE interface Crossover
Cable; point is, how I can use that cable.
I want to use the WIC2T interface of router as DTE interface but the cable
side that can go into WIC2T is DCE.
saleem
-----Original Message-----
From: Scott Morris [mailto:smorris@ipexpert.com]
Sent: Friday, November 09, 2007 8:54 PM
To: 'Muhammad Saleem'; ccielab@groupstudy.com
Subject: RE: How to use WIC2T with opposite type of connectors in
Frame-relay environment?
Companies make some SS-DB60 cables exactly for that in a lab environment.
Otherwise, if you have the "real" cables that terminate in v.35 connectors
they will fit together just fine!
http://www.anthonypanda.com/product.php?prd_id=9&opt_id=29
HTH
Scott Morris, CCIE4 (R&S/ISP-Dial/Security/Service Provider) #4713, JNCIE-M
#153, JNCIS-ER, CISSP, et al.
CCSI/JNCI-M/JNCI-ER
VP - Technical Training - IPexpert, Inc.
IPexpert Sr. Technical Instructor
A Cisco Learning Partner - We Accept Learning Credits!
Telephone: +1.810.326.1444
Fax: +1.810.454.0130
http://www.ipexpert.com
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Muhammad Saleem
Sent: Friday, November 09, 2007 12:33 PM
To: ccielab@groupstudy.com
Subject: How to use WIC2T with opposite type of connectors in Frame-relay
environment?
Dear Expert,
I have Cisco 2610XM router with one WIC2T and one WIC1T, from WIC2T both
interfaces are HD Smart Serial, and two cables with HD Smart Serial
connector End (DCE) that can only go to that router and other End of these
cables have DB60 connector (DTE) that can only go to frame-relay switches.
How can I use these cables with frame-relay switch while cables have
opposite type of connectors?
saleem
This archive was generated by hypermail 2.1.4 : Sat Dec 01 2007 - 06:37:29 ART