From: Brian Dennis (bdennis@internetworkexpert.com)
Date: Sat Oct 27 2007 - 00:59:51 ART
It's not really worth the extra cost to have it in your lab.
Brian Dennis, CCIE4 #2210 (R&S/ISP-Dial/Security/SP)
bdennis@internetworkexpert.com
Internetwork Expert, Inc.
http://www.InternetworkExpert.com
Toll Free: 877-224-8987
Direct: 775-745-6404 (Outside the US and Canada)
>----- Original Message -----
Subject: Re: Configure 2811 HWIC-4ESW PoE
Date: Fri, October 26, 2007 19:49
From: "WorkerBee" <ciscobee@gmail.com>
> Thanks for the feedback. Yes, I really don't have ILS in all my 03 x
> 2811 routers.
>
> It seems like getting ILS + HWIC-4ESW-PoE is still more cost effective
> than owning 03 x 3560-24-PoE or 03 x 3560-8-PoE switches. I am not
> getting the Cat6k so I am using
> another router as the branch/hq router.
>
> Is it really worth the trouble to go all out to make ISR inline power
> capable? Does the Voice lab really test so much on inline power
> configuration? If not, I will probably get some power injector which
> is more cost effective.
>
>
>
> On 10/27/07, Brian Dennis <bdennis@internetworkexpert.com> wrote:
> > Do you have the inline power supply installed or a standard power
> > supply? You'll need the inline power supply in addition to the PoE
> > daughter card. You can tell what you have by issuing the show power
> > inline (if you get output like below you have inline power) or by just
> > looking at the back of the 2811. If it's an inline power supply the
> > power supply will have a little black phone it.
> >
> > R1#show power inline
> > PowerSupply SlotNum. Maximum Allocated Status
> > ----------- -------- ------- --------- ------
> > INT-PS 0 160.000 12.600 PS GOOD
> > Interface Config Device Powered PowerAllocated
> > --------- ------ ------ ------- --------------
> > Fa0/1/0 auto Cisco On 6.300 Watts
> > Fa0/1/1 auto Cisco On 6.300 Watts
> > Fa0/1/2 auto Unknown Off 0.000 Watts
> > Fa0/1/3 auto Unknown Off 0.000 Watts
> > R1#
> >
> > HTH,
> >
> > Brian Dennis, CCIE4 #2210 (R&S/ISP-Dial/Security/SP)
> > bdennis@internetworkexpert.com
> >
> > Internetwork Expert, Inc.
> > http://www.InternetworkExpert.com
> > Toll Free: 877-224-8987
> > Direct: 775-852-3995 (Outside the US and Canada)
> >
> > WorkerBee wrote:
> > > Anyone knows how to make this PoE card work? I tried connecting an IP
> > > Phone to the port, it shows as down and not supply power to the IP
> > > Phone. It is up when I connect to another switch. I am getting rid of
> > > 3560-PoE switches for space saving cards instead.
> > >
> > > I am running 12.4(15)T1 image but under the interface configuration
> > > mode, I don't see anything related to command 'power inline....'.
> > >
> > > I am sure the card is recognize as follows:
> > >
> > > Yaka#show inventory
> > > NAME: "4 Port FE Switch on Slot 0 SubSlot 3", DESCR: "4 Port FE Switch"
> > > PID: HWIC-4ESW , VID: VN/A, SN: FOC09453V5Y
> > >
> > > NAME: "WIC/VIC/HWIC 3 Power Daughter Card", DESCR: "4-Port HWIC-ESW
> > > Power Daughter Card"
> > > PID: ILPM-4 , VID: VN/A, SN: FOC09454GU0
> > >
> > >
> > > Yaka#show ip int brief
> > > Interface IP-Address OK? Method Status
> > > Protocol
> > > FastEthernet0/3/0 unassigned YES unset up
down
> > > FastEthernet0/3/1 unassigned YES unset up
down
> > > FastEthernet0/3/2 unassigned YES unset up
down
> > > FastEthernet0/3/3 unassigned YES unset up
down
> > >
> > > _______________________________________________________________________
> > > Subscription information may be found at:
> > > http://www.groupstudy.com/list/CCIELab.html
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
This archive was generated by hypermail 2.1.4 : Fri Nov 16 2007 - 13:11:18 ART