Re: FR-EEK on interface and subinterface

From: Bit Gossip (bit.gossip@chello.nl)
Date: Sun Jul 29 2007 - 16:14:59 ART


Group,
I have tested now EEK on multipoint subinterface:
- if the subinterface has only ONE dlci, FREEK brings down the subinterface
as soon as it fails
- if the subinterface has more dlci and one fails, FREEK doesn't bring down
the subinterface
- if the subinterface has more dlci and all of them fail, FREEK does bring
down the subinterface

My questions:
- is it possible to configure freek so that it brings down a multipoint
subinterface when it fails on only one dlci?
- is it possible to use SLA to bring down an interface when it fails?
If possible, how is the config?

Thanks,
bit.

interface Serial0/0
 no ip address
 encapsulation frame-relay
 no fair-queue
 clock rate 128000
 no frame-relay inverse-arp
!
interface Serial0/0.105 multipoint
 ip address 1.1.1.1 255.255.255.0
 frame-relay class FREEK
 frame-relay map ip 1.1.1.2 102 broadcast
 frame-relay map ip 1.1.1.5 105 broadcast
!
map-class frame-relay FREEK
 frame-relay end-to-end keepalive mode bidirectional

----- Original Message -----
From: "Greg Wendel" <gwendel@gmail.com>
To: "Bit Gossip" <bit.gossip@chello.nl>
Cc: <ccielab@groupstudy.com>
Sent: Sunday, July 29, 2007 9:13 AM
Subject: Re: FR-EEK on interface and subinterface

> Hello,
> EEK can only be used to bring down the sub interfaces. The physical
> interfaces will remain up as long as they are receiving lmi's from their
> local (CO) frame switch.
>
> Let me know if you need any more information,
>
> Greg
>
> On 7/29/07, Bit Gossip <bit.gossip@chello.nl> wrote:
>>
>> Experts,
>> in my lab I eperience the following behavior, can you confirm that it is
>> as it
>> should be.....
>>
>> - if I apply EEK on a FR physical interface, when EEK goes down the
>> interface
>> stays up
>> - if I apply EEK on a p2p FR subinterface, when EEK goes down the
>> sub-interface goes down as well whether the EEK class is applied to the
>> sub-interface or inside the 'frame-relay interface-dlci'
>>
>> ~ I suspect, but haven't tried yet, that a multipoint subinterface has
>> same
>> behavior as the physical interface, is it true?
>> ~ How can I have EEK bring down the physical interface then?
>>
>> Thanks,
>> bit.
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html
>>
>
>
>
> --
> Gregory Wendel
> Springfield VA, 22153
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html



This archive was generated by hypermail 2.1.4 : Sat Aug 18 2007 - 08:17:42 ART