From: Greg Wendel (gwendel@gmail.com)
Date: Sun Jul 29 2007 - 04:13:33 ART
Hello,
EEK can only be used to bring down the sub interfaces. The physical
interfaces will remain up as long as they are receiving lmi's from their
local (CO) frame switch.
Let me know if you need any more information,
Greg
On 7/29/07, Bit Gossip <bit.gossip@chello.nl> wrote:
>
> Experts,
> in my lab I eperience the following behavior, can you confirm that it is
> as it
> should be.....
>
> - if I apply EEK on a FR physical interface, when EEK goes down the
> interface
> stays up
> - if I apply EEK on a p2p FR subinterface, when EEK goes down the
> sub-interface goes down as well whether the EEK class is applied to the
> sub-interface or inside the 'frame-relay interface-dlci'
>
> ~ I suspect, but haven't tried yet, that a multipoint subinterface has
> same
> behavior as the physical interface, is it true?
> ~ How can I have EEK bring down the physical interface then?
>
> Thanks,
> bit.
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
-- Gregory Wendel Springfield VA, 22153
This archive was generated by hypermail 2.1.4 : Sat Aug 18 2007 - 08:17:42 ART