From: Brian Dennis (bdennis@internetworkexpert.com)
Date: Sat Apr 28 2007 - 17:33:16 ART
This link should help:
http://www.internetworkexpert.com/resources/backtoback-framerelay.htm
--Brian Dennis, CCIE4 #2210 (R&S/ISP-Dial/Security/SP) bdennis@internetworkexpert.com Internetwork Expert, Inc. http://www.InternetworkExpert.com Toll Free: 877-224-8987 Direct: 775-745-6404 (Outside the US and Canada)
On 4/28/07 9:23 AM, "premkumar somasundaram" <premkumar.somasundaram@gmail.com> wrote:
> Group , > When I am configuring frame relay back to back over the serial connection, > the link stays up for 30 odd seconds and it goes down. R4 & R5 are > connected via serial link and I would like to configure frame relay back to > back over that . Here is the configuration.... > > R4 > > interface Serial2/1 > no ip address > encapsulation frame-relay > ! > interface Serial2/1.1 point-to-point > ip address 145.1.45.4 255.255.255.0 > frame-relay interface-dlci 111 > > R5 > interface Serial2/1 > no ip address > encapsulation frame-relay > clock rate 64000 > no dce-terminal-timing-enable > ! > interface Serial2/1.1 point-to-point > ip address 145.1.45.5 255.255.255.0 > frame-relay interface-dlci 111 > > > Am I missing some thing here.. > > > Thanks in advance. > prem > > _______________________________________________________________________ > Subscription information may be found at: > http://www.groupstudy.com/list/CCIELab.html
This archive was generated by hypermail 2.1.4 : Tue May 01 2007 - 08:28:38 ART