From: acybox-groupstudy@yahoo.com
Date: Sun Oct 01 2006 - 10:34:31 ART
Just little bir more findings, debug output from FRA switch just before LMI
goes down:
Mar 1 00:58:24.195: Serial4: FR invalid/unexpected pak received
on DLCI 1023
Mar 1 00:58:34.195: Serial4: FR invalid/unexpected pak received
on DLCI 1023
These are the packets marked with DE bit.
Rings a bell ?
Thanks,
----- Original Message ----
From: "acybox-groupstudy@yahoo.com"
<acybox-groupstudy@yahoo.com>
To: ccielab@groupstudy.com
Sent: Sunday, October
1, 2006 2:21:51 PM
Subject: IE VOL1 LAB7 Q. 8.3 Strange behavior
I am having
an interesting behavior here.
For the ones that don't have IE Labs, question
simply asks to set all the traffic other than dscp CS5 with frame relay DE
bit.
I am doing this with a service-police (also checked the answers). The
problem is that as soon as I apply this service policy to the interface I
loose LMI connectivty and PVC comes down.
Any ideas ?
class-map match-all
CS5
match dscp cs5
policy-map CS5
class CS5
class class-default
set fr-de
int se 0/0
service-policy out CS5
This archive was generated by hypermail 2.1.4 : Wed Nov 01 2006 - 07:29:03 ART