Re: OT : VOIP doubts

From: Dan.Thorson@seagate.com
Date: Fri Sep 29 2006 - 09:30:15 ART


> I have problems with FXO port remaining connected even after
> the calling party hang up..

I have seen similar issues as we've moved our FXO ports from one PBX to
another. Our solution? In the "voice-port" configuration try
adding/removing the "opx" keyword in the "connection plar" command

PBX brand X
      voice-port 2/0/4
       connection plar opx 1000

PBX brand Y
      voice-port 2/0/4
       connection plar 1000

Be sure to "shut / no-shut" the voice-port to get this to take effect.

danT

===================================================
Dan Thorson - Seagate Technology - CCIE 10754
desk +1 (952) 402-8293 fax +1 (952) 402-1007
SeaTel 8-402-8293
===================================================