RE: What Formula's ?

From: uyota oyearone (spycharlies@hotmail.com)
Date: Thu Jul 20 2006 - 17:35:31 ART


bc=cir/8 is only true for when the Tc=125ms.

  --------------------------------------------------------------------

  From: rwcrowe@nc.rr.com
  Reply-To: rwcrowe@nc.rr.com
  To: ccielab@groupstudy.com
  Subject: What Formula's ?
  Date: Thu, 20 Jul 2006 14:20:33 -0400
>Ok,
>
> It seems that there are alot of different formulas that people
  are
>using for bc and be for the lab. Can I get a consensus of how people
>calculate the below ?
>
>rate-limit command = CIR/8 * 1.5
>police = bc is CIR/8 * 1.5 be = bc * 2
>shape = ?
>frame-relay bc = CIR*TC/1000
>frame-relay be = AR-CIR*TC/1000
>