FREEK end to end keep alive parameters

From: Pierre-Alex (paguanel@hotmail.com)
Date: Fri Jun 09 2006 - 13:17:20 ART


Is this correct? Is there something else to it?

The command "frame-relay end-to-end keepalive event-window" set total number
of errors that can be recorded: the bin

When a keepalive is missed the bin is incremented by one and then when the
event-window has accumlated to a certain value determined by the "frame-relay
end-to-end keepalive error-threshold:" the interface goes down.

Lets suppose that the bin is set for 32 errors (the max for event-window),
and the interface goes down after 3 errors (the error-threshold) .

If no keepalive is received, after 3 missed the interface goes down. Lets say
there are no keepalives for another 17 keepalive cycles, then thing start
working again.

The "frame-relay end-to-end keepalive success-events" will determine how many
successive keepalive to put the interface up.

(As I understand it, the event-window would be reset to zero after that)

To summurize:

"frame-relay end-to-end keepalive success-events" the number of consecutive
success events required to change the keepalive state from down to up.

"frame-relay end-to-end keepalive error-threshold: Number of errors in the
event window before keepalive status goes from up to down."

"frame-relay keepalive event-window" : the bin recording the errors - There
are no bin recording consecutive successes !

http://www.cisco.com/univercd/cc/td/doc/product/software/ios124/124cr/hwan_r/
wan_f1h.htm#wp1072084



This archive was generated by hypermail 2.1.4 : Sat Jul 01 2006 - 07:57:32 ART