From: Adam S. Roth (adam@therothfamily.net)
Date: Sat May 27 2006 - 07:37:35 ART
That was the answer. Thank you!
This email message and any attachments are intended for the use of the
addressee(s) indicated above. Information that is privileged or otherwise
confidential may be contained herein. If you are not the intended
recipient(s), you are hereby notified that any dissemination, review, or use
of this message, documents, or information contained herein is strictly
prohibited.
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of Rick
Fox
Sent: Friday, May 26, 2006 8:56 PM
To: Adam S. Roth; ccielab@groupstudy.com
Subject: RE: OSPF - NMC Lab 2
Make sure the MTU are the same on both router interfaces - Vlan 40 is set
to 1504 from the output below. Or use the ip ospf mtu-ignore on the
interface.
Just a thought.
Rick
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of Adam
S. Roth
Sent: Friday, May 26, 2006 8:17 PM
To: ccielab@groupstudy.com
Subject: OSPF - NMC Lab 2
I am kind of stuck. I did some searching online, on Cisco and some group
study archive searching and still cant get the following error message to
stop :
00:21:45: %OSPF-5-ADJCHG: Process 1, Nbr 172.16.102.1 on Vlan40 from DOWN to
DOW N, Neighbor Down: Dead timer expired
00:23:02: %OSPF-5-ADJCHG: Process 1, Nbr 172.16.102.1 on Vlan40 from EXSTART
to DOWN, Neighbor Down: Too many DBD retransmitions
00:23:45: %OSPF-5-ADJCHG: Process 1, Nbr 172.16.102.1 on Vlan40 from DOWN to
DOW N, Neighbor Down: Dead timer expired00:27:02: %OSPF-5-ADJCHG: Process 1,
Nbr 172.16.102.1 on Vlan40 from EXSTART to DOWN, Neighbor Down: Too many DBD
retransmitions
Orginally , by mistake I assign the same loop back to R2 and Cat1. I
removed the wrong one, did a write mem and then a reboot and those messages
above appeared.
I checked duplex, here is vlan 40 from CAT1
Vlan40 is up, line protocol is up
Hardware is EtherSVI, address is 000a.b712.9680 (bia 000a.b712.9680)
Internet address is 172.16.20.10/25
MTU 1504 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:05, output 00:00:07, output hang never
Last clearing of "show interface" counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 4
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
352 packets input, 32794 bytes, 0 no buffer
Received 0 broadcasts (0 IP multicast)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
343 packets output, 30928 bytes, 0 underruns
0 output errors, 0 interface resets
0 output buffer failures, 0 output buffers swapped out
What else should I check?
Thanks
Adam
This archive was generated by hypermail 2.1.4 : Thu Jun 01 2006 - 06:33:22 ART