RE: Bring up an interface at a specific time?

From: de Witt, Duane (duane.dewitt@siemens.com)
Date: Wed Jan 04 2006 - 02:34:57 GMT-3


Hi Scott

Would it be possible for you to send an example config?

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Scott Morris
Sent: 04 January 2006 03:14 AM
To: 'Brian Dennis'; 'Mike Ollington'; ccielab@groupstudy.com
Subject: RE: Bring up an interface at a specific time?

You could use kron to do things like shut and no shut your interface as
well.

http://www.cisco.com/en/US/products/ps6350/products_configuration_guide_
chap
ter09186a008045592c.html

In the kron policy list, you can specify which user you are logging in
as
and do things in config mode as well. You would use the "config-cli" as
part of the option.

Two polcies. One at 8am turns it on, another at 5pm turns it off.
Kinda a
festive way to do things! Less complicated IMHO than creating a GRE to
go
along with stuff.

Scot

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Brian Dennis
Sent: Tuesday, January 03, 2006 5:31 PM
To: Mike Ollington; ccielab@groupstudy.com
Subject: RE: Bring up an interface at a specific time?

Use a GRE tunnel and have the PPP/T1 link as the backup interface for
the
GRE tunnel. When it's time for the PPP/T1 to come up, have a time based
ACL
deny the GRE traffic so that the tunnel goes down and the backup kicks
in.

HTH,

Brian Dennis, CCIE #2210 (R&S/ISP-Dial/Security)
bdennis@internetworkexpert.com
 
Internetwork Expert, Inc.
http://www.InternetworkExpert.com
Toll Free: 877-224-8987
Direct: 775-745-6404 (Outside the US and Canada)
 

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Mike
Ollington
Sent: Tuesday, January 03, 2006 2:03 PM
To: ccielab@groupstudy.com
Subject: Bring up an interface at a specific time?

Hello,

Not sure if I'm over thinking this requirement - I have a PPP T1 circuit
that should not be `up' between 5pm and 8am, however, it should be up/up
between 8am and 5pm.

Is there a feature to do this or just a bit of lateral thinking?

Thanks,
Mike



This archive was generated by hypermail 2.1.4 : Wed Feb 01 2006 - 07:45:47 GMT-3