RE: Bring up an interface at a specific time?

From: Brian Dennis (bdennis@internetworkexpert.com)
Date: Tue Jan 03 2006 - 19:30:41 GMT-3


Use a GRE tunnel and have the PPP/T1 link as the backup interface for
the GRE tunnel. When it's time for the PPP/T1 to come up, have a time
based ACL deny the GRE traffic so that the tunnel goes down and the
backup kicks in.

HTH,

Brian Dennis, CCIE #2210 (R&S/ISP-Dial/Security)
bdennis@internetworkexpert.com
 
Internetwork Expert, Inc.
http://www.InternetworkExpert.com
Toll Free: 877-224-8987
Direct: 775-745-6404 (Outside the US and Canada)
 

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Mike Ollington
Sent: Tuesday, January 03, 2006 2:03 PM
To: ccielab@groupstudy.com
Subject: Bring up an interface at a specific time?

Hello,

Not sure if I'm over thinking this requirement - I have a PPP T1 circuit
that should not be `up' between 5pm and 8am, however, it should be up/up
between 8am and 5pm.

Is there a feature to do this or just a bit of lateral thinking?

Thanks,
Mike



This archive was generated by hypermail 2.1.4 : Wed Feb 01 2006 - 07:45:47 GMT-3