RE: OSPF Area 0 Tuneling

From: Schulz, Dave (DSchulz@dpsciences.com)
Date: Wed Nov 09 2005 - 11:52:24 GMT-3


Ok, thanks. I'll have to lab that one up. I have always assumed that
it needed to be on the same subnet.

Dave Schulz,

Email: dschulz@dpsciences.com <mailto:dschulz@dpsciences.com%20>

________________________________

From: manoj menon [mailto:manojmenon123@yahoo.com]
Sent: Wednesday, November 09, 2005 9:14 AM
To: Schulz, Dave; Dave Temkin; Dan Agache
Cc: De Witt, Duane; Cisco certification
Subject: RE: OSPF Area 0 Tuneling

Hi dave,

this was once discussed a few weeks ago. You can do this with ip
unnumbered loopback 0' provided you introduce the loopback 0 of both
routers into area 0. Doing so, we have just extended the area 0 on to
the far end router.

regards

manoj

"Schulz, Dave" <DSchulz@dpsciences.com> wrote:

        This brings up a question....Since the tunnel is specifically
being used
        to extend area 0, and the tunnel must have both ends in the same
subnet.
        Doesn't this tunnel have to be an assigned ip address that is on
the
        same subnet (both ends of the tunnel)? And, this subnet would
then have
        to be assigned to area 0. Can this even be done with ip
unnumbered?

        Dave Schulz,

        Email: dschulz@dpsciences.com

        -----Original Message-----
        From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On
Behalf Of
        Dave Temkin
        Sent: Wednesday, November 09, 2005 8:15 AM
        To: Dan Agache
        Cc: De Witt, Duane; Cisco certification
        Subject: Re: OSPF Area 0 Tuneling

        Be sure to read the wording of the lab carefully. They may (or
may not)
        allow you to create additional IP addressing within a certain
scope, as
        needed.

        Using ip unnumbered to a loopback isn't all that great of an
idea, as
        your
        loopbacks will generally be in different subnets.

        -Dave

        On Wed, 9 Nov 2005, Dan Agache wrote:

> I think that you have to use all that the lab is given,
nothing more.
        Using another subnet address is extra commands and is not a good
idea.
        That's my opinion.
>
>
> "De Witt, Duane" wrote:
> Hi Group
>
>
>
> Quick question: in the lab if you have to join discontiguous
area 0's
> with tunnels is it better to use ip unnumbered loopback 0
(assuming
> loopback 0 is in area 0) or a new IP address and add the new
subnet to
> area 0 as well as the loopback.
>
>
>
> I'm asking this because in IEWB V2 Lab3, area 0 consists of
the
        loopback
> interface of each router. So a tunnel was used using ip
unnumbered
> loopback 0. My solution was to create a new subnet for the
tunnel and
> add it to area 0.
>
>
>
> Regards
>
> Duane
>
>
>
> ____________________________________________
> SIEMENS Siemens Business Services
> Siemens Service Center
>
> 126 14th Road
>
> Erand Gardens
>
> Midrand
>
> South Africa
>
>
>
> * +27 11 5452555
> * +27 83 4452768
> * +27 11 5415219
> * duane.dewitt@siemens.com
>
>



This archive was generated by hypermail 2.1.4 : Thu Dec 01 2005 - 09:12:05 GMT-3