Re: state - EXSTART/DR

From: Arun Arumuganainar (aarumuga@hotmail.com)
Date: Tue Nov 08 2005 - 08:58:08 GMT-3


Configure MTU or IP MTU on the switch to be 1500 .

By default it would be 1496 on a switch . I believe this will solve your
problems .

Thanks and Regards
Arun
----- Original Message -----
From: "Jerricho Grivano" <Jerricho.Grivano@metrodata.co.id>
To: <ccielab@groupstudy.com>
Sent: Tuesday, November 08, 2005 4:55 PM
Subject: state - EXSTART/DR

> Hi, anybody can help me? why the state EXSTART/DR, and i get message in
SW1 :
>
> Rack2SW1#
> 16:18:47: %OSPF-5-ADJCHG: Process 2, Nbr 150.2.2.2 on FastEthernet0/2 from
EXSTART to DOWN, Neighbor Down: Too many DBD retransmitions
>
>
> Rack2R2#sh ip ospf neigh
>
> Neighbor ID Pri State Dead Time Address
Interface
> 150.2.1.1 1 FULL/DR 00:01:36 191.2.125.1
Serial0/0
> 150.2.3.3 0 FULL/ - 00:00:35 191.2.23.3
Serial0/1
> 150.2.7.7 1 EXSTART/DR 00:00:38 191.2.27.7
FastEthernet0/0
>
>
> Thanks
> Jerricho
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html



This archive was generated by hypermail 2.1.4 : Thu Dec 01 2005 - 09:12:05 GMT-3