Flowcontrol on Fiber Interfaces

From: McNeace, Roger (RMcNeace@ciena.com)
Date: Mon Feb 07 2005 - 18:56:29 GMT-3


 Catalyst 6500, CatOS 8.3.(4)

I recently had some issues with slow responding Netapp appliances. According to Netapp flowcontrol needs to be applied to the switch interface.

set port flowcontrol 11/48 send on
set port flowcontrol 11/48 recieve on

Question: I know this has something to do with buffers and sending pause frames, but when do I know when this is needed other than calling the NIC manufacturer of the attached device? Looked up commands on Cisco website but failed to get any technical insight. Thanks

Roger McNeace CCIE#12777
Prinicipal Network Engineer
Ciena Corporation
410-694-5805
rmcneace@ciena.com