Thanks for putting me straight about this. Examination of the ospf database I think confirms your explaination.

Regards, Chris.

-----Original Message-----
From: Carlos G Mendioroz [mailto:tron@huapi.ba.ar]
Sent: 10 October 2004 13:13
To: Lord, Chris
Cc: ccielab@groupstudy.com
Subject: Re: ISDN Backup and OSPF Virtual Links

No, I think you don't neet that second VL.
R2-R3 may be physically down, but it's logically up.
R2 knows R3 info, and given the link is demand circuit, it keeps that
knowledge (DNA + no hellos). There are no 2 area 2 instances, only one.

Lord, Chris wrote:
> I have the following scenario......
>
> R2----FR1---R1----FR2-----R3--Ethe
> R2----------ISDN--------------R3
>
> The FR link between R1 and R2 is in ospf area 0
> The FR link between R1 and R3 plus the R3 ethernet are all in area 1
> The ISDN link is in area 2
> (the frame relay links are independant i.e. not hub-and-spoke)
>
> The ISDN is being used to backup the R1-R3 FR2 link and I am using demand circuit.
>
> Hope this makes sense so far!
>
> My question is what virtual links do I need??
>
> Obviously I need a VL between R2 and R3 (isdn link) because when the FR2 goes down area 1 becomes an isolated area on R3 ethernet.
>
> But, do I also need a VL between R1 and R3 for normal conditions? My logic is this... under normal conditions, the bri interfaces are up but the ISDN is down, so, we have two area 3s - one on the R3 bri intf and a second on the R2 bri intf - but unconnected. So under normal circumstances Area 3 on the R3 bri intf is isolated from the backbone area 0.
>
> In practice I don't think it makes any difference to the functioning of the network whether there is a VL between R1 and R3 or not. However, for the exam, is it good practice to do so??
>
> What d'ya think?
>
> TIA
>
> Chris
>
>
>
> **********************************************************************
> The information contained in this email is confidential and is intended for the recipient only. If you have received it in error, please notify us immediately by reply email and then delete it from your system. Please do not copy it or use it for any purposes, or disclose its contents to any other person or store or copy this information in any medium. The views contained in this email are those of the author and not necessarily those of Lorien plc.
>
> Thank you for your co-operation.
> **********************************************************************
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>

-- 
Carlos G Mendioroz  <tron@huapi.ba.ar>  LW7 EQI  Argentina