From: James (james@towardex.com)
Date: Thu Sep 16 2004 - 13:19:18 GMT-3
On Thu, Sep 16, 2004 at 03:52:23PM +0000, W Walla wrote:
> /Hello good people-
>
> I have a question on how this hub and spoke is configured. I have a full
> T1 on both side but the HUB shows timeslots 1-24 and the spoke side doesn't
> have that sommand. How is this affecting performance, what should be done
> to take advantage of the Full T1 between the two. Also, the HUB has other
> spokes it shares with the "spoke" in question they are all 256k with
> timeslots 1-4 command.. Thanks!
By default, timeslots are 1-24.
The timeslots shouldn't be determined by you in general per se, it
should be determined by what type of contract you purchase from the
telco w/ respect to a particular circuit.
If you are buying a fractional 384k frame circuit at one location,
then it would be 1-6 for the timeslot. The hub site would remain
at 1-24, assuming the hub site's circuit ID in telco's database
says it is a full T1, and assuming the hub site's circuit is really
full T1.
-J
-- James Jun TowardEX Technologies, Inc. Technical Lead Network Design, Consulting, IT Outsourcing james@towardex.com Boston-based Colocation & Bandwidth Services cell: 1(978)-394-2867 web: http://www.towardex.com , noc: www.twdx.net
This archive was generated by hypermail 2.1.4 : Fri Oct 01 2004 - 15:00:45 GMT-3