From: gladston@br.ibm.com
Date: Mon Sep 13 2004 - 19:15:05 GMT-3
If the CBWFQ is applyed on the main interface (encaps frame-relay, without shaping) is the behavior any different (concerned to the available bandwidth)?
==========
quoted
When the bandwidth and priority commands calculate the total amount of bandwidth available on an entity, the following guidelines are invoked when the entity is a shaped Frame Relay permanent virtual circuit (PVC):
If a Minimum Acceptable Committed Information Rate (minCIR) is not configured, the CIR is divided by two.
If a minCIR is configured, the minCIR setting is used in the calculation.
The full bandwidth from the above rate can be assigned to bandwidth and priority classes. Thus, the max-reserved-bandwidth command is not supported on Frame Relay PVCs, although you should take care to ensure that the amount of bandwidth configured is large enough to also accommodate Layer 2 (L2) overhead
===========
This archive was generated by hypermail 2.1.4 : Fri Oct 01 2004 - 15:00:42 GMT-3