From: Carlos G Mendioroz (tron@huapi.ba.ar)
Date: Tue Aug 31 2004 - 14:25:09 GMT-3
Gladston,
it would help if you:
-clear counters before the test (noticed quite a bit of drops there, but
also quite a bit of traffic)
-include also the map-class (i.e. all relevant configuration)
-don't clip the history from the messages.
But 700 bytes should fit in your 875 bytes Bc, unless you are doing
something else at the same time...
gladston@br.ibm.com wrote:
> Thanks Bob and Carlos,
>
> Here is the result of debug frame frag (or should I say "no result", eh,eh)
> And the result of show fram pvc 302 with the full configuration.
> No police. Maybe the version? (2500 with 12.2(1d))
>
>
> r3#debu frame-relay fra ev
> This may severely impact network performance.
> You are advised to enable 'no logging console debug'. Continue?[confirm]
> Frame Relay fragment event/errors debugging is on
> r3#
> r3#
> r3#cl
> Clear logging buffer [confirm]
> r3#p
> Protocol [ip]:
> Target IP address: 172.16.23.2
> Repeat count [5]:
> Datagram size [100]: 700
> Timeout in seconds [2]:
> Extended commands [n]:
> Sweep range of sizes [n]:
> Type escape sequence to abort.
> Sending 5, 700-byte ICMP Echos to 172.16.23.2, timeout is 2 seconds:
> .....
> Success rate is 0 percent (0/5)
> r3#sl
> Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes,
> 0 overruns)
> Console logging: disabled
> Monitor logging: level debugging, 0 messages logged
> Buffer logging: level debugging, 68 messages logged
> Logging Exception size (4096 bytes)
> Trap logging: level informational, 71 message lines logged
>
> Log Buffer (4096 bytes):
> r3#
>
> r3#show frame pvc 302
>
> PVC Statistics for interface Serial0 (Frame Relay DTE)
>
> DLCI = 302, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.32
>
> input pkts 66925 output pkts 16667 in bytes 4341773
> out bytes 910493 dropped pkts 65 in FECN pkts 0
> in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
> in DE pkts 0 out DE pkts 0
> out bcast pkts 0 out bcast bytes 0
> pvc create time 5d20h, last time pvc status changed 4d02h
> Queueing strategy: weighted fair
> Current fair queue configuration:
> Discard Dynamic Reserved
> threshold queue count queue count
> 64 16 0
> Output queue size 0/max total 600/drops 0
> fragment type end-to-end fragment size 500
> cir 56000 bc 7000 be 0 limit 875 interval 125
> mincir 28000 byte increment 875 BECN response no
> frags 251 bytes 23536 frags delayed 244 bytes delayed 22909
>
> shaping inactive
> traffic shaping drops 0
>
> r3#sh conf
> !
> interface Serial0
> no ip address
> encapsulation frame-relay
> ip ospf network point-to-point
> frame-relay traffic-shaping
> frame-relay lmi-type cisco
> !
> interface Serial0.32 multipoint
> ip address 172.16.23.3 255.255.255.0
> frame-relay class Frame
> frame-relay map ip 172.16.23.2 302 broadcast
> !
> interface Serial0.34 multipoint
> ip address 172.16.34.3 255.255.255.0
> frame-relay map ip 172.16.34.4 304 broadcast
> !
> interface Serial1
> no ip address
> shutdown
>
> _______________________________________________________________________
> Please help support GroupStudy by purchasing your study materials from:
> http://shop.groupstudy.com
>
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
-- Carlos G Mendioroz <tron@huapi.ba.ar> LW7 EQI Argentina
This archive was generated by hypermail 2.1.4 : Fri Sep 03 2004 - 07:02:51 GMT-3