From: Dave Meyer (dave.meyer@db.com)
Date: Wed Aug 25 2004 - 13:06:01 GMT-3
Just wanted to get some opinions on this.........
Currently have FR circuits with 0 CIR & would like to implement VOIP.
If we purchased a CIR = amount we expect to reserve for VOIP ( no
signaling) , and assigned the appropriate LLQ,
would we expect the voice traffic to be guaranteed by the CIR ?
Regards,
Dave