difference between BOD and Multilink

From: Geert Nijs (geert.nijs@simac.be)
Date: Fri Jun 11 2004 - 08:12:38 GMT-3


Hi all, this is my first question to the ccielab mailing list......

I am looking for detailed information regarding load-balancing using Bandwidth-On-Demand.
I have learned (the hard way!) that there is a difference between ppp multilink and BOD.

Compare the following two BRI configurations (basic DDR config assumed):

int bri0
        dialer load-threshold 10

and

int bri0
        ppp multilink
        ppp multilink load-threshold 10

Both will add a second channel when the load reaches 10/255, however in the first case you don't
really have a ppp multlink, only two seperate channels. I know that when you use ppp multilink
packets are actually split, broken apart, and a piece is put on every link in the multilink. So load-
balancing comes naturally.

But what if you use BOD ? if have tested the first config in my lab, and the load doesn't get
distributed fairly on both channels. How can i force the load to be equally balanced in this case ???
Or what load-distribution algoritme is used with BOD ??
#####################################################################################
This e-mail and any attached files are confidential and may be legally privileged.
If you are not the addressee, any disclosure, reproduction, copying, distribution,
or other dissemination or use of this communication is strictly prohibited.
If you have received this transmission in error please notify Simac immediately
and then delete this e-mail.

Simac has taken all reasonable precautions to avoid virusses in this email.
Simac does not accept liability for damage by virusses, for the correct and complete
transmission of the information, nor for any delay or interruption of the transmission,
nor for damages arising from the use of or reliance on the information.

All e-mail messages addressed to, received or sent by Simac or Simac employees
are deemed to be professional in nature. Accordingly, the sender or recipient of
these messages agrees that they may be read by other Simac employees than the official
recipient or sender in order to ensure the continuity of work-related activities
and allow supervision thereof.
#####################################################################################



This archive was generated by hypermail 2.1.4 : Sat Jul 03 2004 - 19:40:37 GMT-3