From: Kaiser Anwar (kaiseranwar@sbcglobal.net)
Date: Sat Apr 03 2004 - 23:22:38 GMT-3
After spending five hours with trying different things finally sbc admitted
that there is a problem with smart jack and they will send out a technician.
Thanks to all for their help. Just one thing though I was getting lot of
input errors and interface resets I don't know what was causing that. Thanks
Kaiser Anwar
Network engineer
Cell: (847) 409-7261
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Mike Dickson
Sent: Saturday, April 03, 2004 5:46 PM
To: Ccielab@Groupstudy. Com (E-mail)
Subject: RE: line protocol is down
It's a little hard to debug without knowing how the circuit is
provisioned, but assuming that we are dealing with a T1 circuit, I
would have SBC verify the framing and coding on the circuit, and make
sure that the settings on your side match.
Mike Dickson
CCIE #12281, MCSE+Internet, MCDBA
Dickson Network Designs
(512) 422-3192 voice (512) 394-0320 fax
www.dicksonnetworks.com
-----Original Message-----
From: Moffat, Ed [mailto:EMoffat@fsci.com]
Sent: Saturday, April 03, 2004 3:35 PM
To: 'Kaiser Anwar'; 'Ccielab@Groupstudy. Com (E-mail)'
Subject: RE: line protocol is down
Have you checked the configurations and errors on your DSUs?
-----Original Message-----
From: Kaiser Anwar [mailto:kaiseranwar@sbcglobal.net]
Sent: Saturday, April 03, 2004 1:30 PM
To: 'Neil Moore'; 'Ccielab@Groupstudy. Com (E-mail)'
Subject: RE: line protocol is down
It is simply point to point with ser up on both sides and line down. I
have tried every combination. On one side I am getting lot of input
errors. As soon as I clear them I get them again. Thanks
Kaiser Anwar
Network engineer
Cell: (847) 409-7261
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf
Of
Neil Moore
Sent: Saturday, April 03, 2004 3:19 PM
To: Kaiser Anwar; Ccielab@Groupstudy. Com (E-mail)
Subject: Re: line protocol is down
The physical interface being down, Incorret DLCI on the frameswitch or
interface would do it.
Please email in the physical and point-to-p conifg along with a show
frame map
----- Original Message -----
From: "Kaiser Anwar" <kaiseranwar@sbcglobal.net>
To: "Ccielab@Groupstudy. Com (E-mail)" <ccielab@groupstudy.com>
Sent: Saturday, April 03, 2004 4:05 PM
Subject: line protocol is down
> Hi,
> Just a quick question for point to point what could cause line
> protocol down. Thanks
>
>
> Kaiser Anwar
> Network engineer
> Cell: (847) 409-7261
>
> ______________________________________________________________________
> _ Please help support GroupStudy by purchasing your study materials
> from:
> http://shop.groupstudy.com
>
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
This archive was generated by hypermail 2.1.4 : Mon May 03 2004 - 19:48:42 GMT-3