From: Ahmed Mustafa (ahmed.mustafa@sbcglobal.net)
Date: Mon Feb 16 2004 - 03:55:49 GMT-3
I am not able to bring up both both B channels. When I generate a normal ping
or extended ping with big datagram size, and still it will only bring one
channel up, not both of them. Please see my config below, and let me know if
there are any errors. I am using Astricom ISDN Simulator, not a true ISDN
Switch. Is is because of that.
Thanks,
R4
----------------------------------------------------
interface BRI0
ip address 183.1.45.4 255.255.255.248
encapsulation ppp
ip ospf demand-circuit
dialer map ip 183.1.45.5 name Rack1R5 broadcast 552221
dialer-group 1
isdn switch-type basic-ni
isdn spid1 30355511110101
isdn spid2 30355511120101
ppp authentication pap
ppp pap sent-username Rack1R4 password 0 CISCO
ppp multilink
ppp multilink links-min 2
-----------------------------------------------------------------------------
------
R5
-----------------------------------------------------------------------------
-----
interface BRI0
ip address 183.1.45.5 255.255.255.248
encapsulation ppp
ip ospf demand-circuit
dialer idle-timeout 180 either
dialer map ip 183.1.45.4 name Rack1R4 broadcast 5551111
dialer-group 1
isdn switch-type basic-ni
isdn spid1 30355522220101
isdn spid2 30355522210101
ppp authentication pap
ppp pap sent-username Rack1R5 password 0 CISCO
ppp multilink
multilink min-links 2