From: Church, Chuck (cchurch@wamnetgov.com)
Date: Tue Dec 02 2003 - 13:32:17 GMT-3
Maybe because it doesn't have an IP address on it? Or maybe it's some variation in software versions?
Chuck Church
CCIE #8776, MCNE, MCSE
Wam!Net Government Services
13665 Dulles Technology Dr. Ste 250
Herndon, VA 20171
Office: 703-480-2569
Cell: 703-819-3495
cchurch@wamnetgov.com
PGP key: http://pgp.mit.edu:11371/pks/lookup?op=index&search=cchurch%40wamnetgov.com
> -----Original Message-----
> From: Weidong Xiao [mailto:Weidong.Xiao@vi.net]
> Sent: Tuesday, December 02, 2003 11:26 AM
> To: rnasr; Church, Chuck; EbonyGuru@aol.com; ccielab@groupstudy.com
> Subject: RE: CAT 2900 Issue
>
>
> I'm not sure about that. The following is one of our
> production switch, WS-C3548-XL, the admin vlan is vlan 999,
> and the vlan 1 doesn't need to be admin shutdown.
>
>
> SW3#sh ip int b
> Any interface listed with OK? value "NO" does not have a
> valid configuration
>
> Interface IP-Address OK? Method Status
> Protocol
> VLAN1 unassigned NO unset up
> down
> VLAN999 192.168.95.203 YES NVRAM up
> up
> FastEthernet0/1 unassigned YES unset up
> up
> FastEthernet0/2 unassigned YES unset up
> up
> ....
> FastEthernet0/47 unassigned YES unset up
> up
> FastEthernet0/48 unassigned YES unset down
> down
> GigabitEthernet0/1 unassigned YES unset up
> up
> GigabitEthernet0/2 unassigned YES unset up
> up
> SW3#
>
> > -----Original Message-----
> > From: nobody@groupstudy.com
> [mailto:nobody@groupstudy.com]On Behalf Of
> > rnasr
> > Sent: 01 December 2003 15:50
> > To: 'Church, Chuck'; EbonyGuru@aol.com; ccielab@groupstudy.com
> > Subject: RE: CAT 2900 Issue
> >
> >
> > That's definetly it. You create a new int and "no shut" and
> > the other one
> > will shut down - you can only have one vlan int active at any
> > one time on
> > these switches.
> >
> > James N.
> >
> > -----Original Message-----
> > From: nobody@groupstudy.com
> [mailto:nobody@groupstudy.com]On Behalf Of
> > Church, Chuck
> > Sent: Wednesday, December 03, 2003 2:34 AM
> > To: EbonyGuru@aol.com; ccielab@groupstudy.com
> > Subject: RE: CAT 2900 Issue
> >
> >
> > Since it's a layer 2 only switch, you can only have one
> VLAN interface
> > active at a time. Is that the problem?
> >
> > Chuck Church
> > CCIE #8776, MCNE, MCSE
> > Wam!Net Government Services
> > 13665 Dulles Technology Dr. Ste 250
> > Herndon, VA 20171
> > Office: 703-480-2569
> > Cell: 703-819-3495
> > cchurch@wamnetgov.com
> > PGP key:
> > http://pgp.mit.edu:11371/pks/lookup?op=index&search=cchurch%40
> wamnetgov.com
>
> > -----Original Message-----
> > From: EbonyGuru@aol.com [mailto:EbonyGuru@aol.com]
> > Sent: Tuesday, December 02, 2003 8:30 AM
> > To: ccielab@groupstudy.com
> > Subject: CAT 2900 Issue
> >
> >
> > Dear All,
> >
> > I am currently having problems bringing a vlan interface out
> > of shutdown on the above device.
> >
> > Is there something ovbious I am missing here?
> >
> > Interface Vlan3 is shutdown and determined to remain so.
> > Please advice.
> >
> > EG.
> >
> > ______________________________________________________________
> > _________
> > Please help support GroupStudy by purchasing your study
> > materials from:
> > http://shop.groupstudy.com
> >
> > Subscription information may be found at:
> > http://www.groupstudy.com/list/CCIELab.html
>
> ______________________________________________________________
> _________
> Please help support GroupStudy by purchasing your study
> materials from:
> http://shop.groupstudy.com
>
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
> ______________________________________________________________
> _________
> Please help support GroupStudy by purchasing your study
> materials from:
> http://shop.groupstudy.com
>
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
This archive was generated by hypermail 2.1.4 : Sat Jan 03 2004 - 08:25:34 GMT-3