AW: Etherchannel one way-link question

From: Oliver Ziltener (ziltener@netcloud.ch)
Date: Sun Nov 30 2003 - 15:48:51 GMT-3


Hey Juan
even if you clear vlan 1 on trunks, PAGP is STILL propageted!
You stop only usertraffic and stp!

best regards
Oliver

-----Urspr|ngliche Nachricht-----
Von: jfaure@sztele.com [mailto:jfaure@sztele.com]
Gesendet: Samstag, 29. November 2003 20:47
An: Mujica, Raul - (Per)
Cc: ccielab@groupstudy.com
Betreff: Re: Etherchannel one way-link question

Hi Raul:

What is your native vlan for these Etherchanel trunks? Belong your config i
supose it is vlan 1. As maybe traffic control for PAGP goes through this
vlan, and this vlan isn't allowed in the trunks, i supose this cause link
flapping.

By the other way, if you force the Etherchannel to "no negotiate " (
putting the etherchannel in "on mode") this type of traffic isn't need and
you don't have problems

Anyone can correct if i'm wrong?

Regards

Juan Faure Ferrer
email: jfaure@sztele.com

Lmnea de Negocio de Telematica y CC
Ingeniero de Integracisn de Redes y Sistemas
----------------------------------------------------------------------------

SOLUZIONA TELECOMUNICACIONES
Servicios Profesionales de UNION FENOSA
Jerez, 3
28016 MADRID
tel 91 579 30 00 fax 91 350 72 83
---------------------------------------------------------------------------

 

                    "Mujica, Raul

                    - (Per)" Para: "'ccielab@groupstudy.com'"

                    <raul.mujica@a <ccielab@groupstudy.com>

                    ttla.com> cc:

                    Enviado por: Asunto: Etherchannel one way-link
question
                    nobody@groupst

                    udy.com

 

 

                    29/11/03 07:42

                    Por favor,

                    responda a

                    "Mujica, Raul

                    - (Per)"

 

 

Hi:
I have a pair of questions:

1.- Is UDLD the only choice to manage one-way links ?

2.- When I configure UDLP and PAGP (mode desirable on both sides) on the
interfaces to form an etherchanel, this is flapping, has someone
experienced this ?

interface range FastEthernet0/23-24
 switchport trunk encapsulation dot1q
 switchport trunk allowed vlan 10,20,30
 switchport mode trunk
 no ip address
 udld enable
 channel-group 1 mode desirable

But when I use "mode on" and UDLD, the port-group goes up without problem
and get stable.

interface range FastEthernet0/23-24
 switchport trunk encapsulation dot1q
 switchport trunk allowed vlan 10,20,30
 switchport mode trunk
 no ip address
 udld enable
 channel-group 1 mode on

Regards
Raul



This archive was generated by hypermail 2.1.4 : Fri Dec 12 2003 - 12:29:19 GMT-3