From: Jim Phillipo (jim.phillipo@guardent.com)
Date: Fri Jul 11 2003 - 17:47:50 GMT-3
Sorry, I was not clear.
The lab I am doing required a reserve of 128 with 64 per flow max
On their solution this one router had 7500 7500 ? I am not clear why ?
If you look the sub interfaces have 128 and 64, is there some kind of added
requirement for sub interfaces ?
-----Original Message-----
From: boby2kusa@hotmail.com [mailto:boby2kusa@hotmail.com]
Sent: Friday, July 11, 2003 4:41 PM
To: Jim Phillipo; ccielab@groupstudy.com
Subject: Re: IP rsvp config
means the total allocated is 7500 and for every single stream is 7500
----- Original Message -----
From: "Jim Phillipo" <jim.phillipo@guardent.com>
To: <ccielab@groupstudy.com>
Sent: Friday, July 11, 2003 12:18 PM
Subject: IP rsvp config
> Could someone explain what the purpose of the 7500 setting is doing on the
> main Ethernet interface ?
>
> This is from a IPEXPERT lab and I found it confusing
>
>
>
> !<?xml:namespace prefix = o ns = "urn:schemas-microsoft-com:office:office"
> />
>
> interface Ethernet1/0
>
> no ip address
>
> ip rsvp bandwidth 7500 7500
>
> ip rsvp signalling dscp 0
>
> !
>
> interface Ethernet1/0.1
>
> encapsulation dot1Q 56
>
> ip address 140.10.56.6 255.255.255.0
>
> ip rsvp bandwidth 128 64
>
> !
>
> interface Ethernet1/0.2
>
> encapsulation dot1Q 76
>
> ip address 140.10.76.6 255.255.255.0
>
> ip rsvp bandwidth 128 64
>
> Jim Phillipo, CCNP, CCDP
> Sr. Internetworking Engineer
> W: 401.456.1821 F: 401.456.0599 M: 508.982.8923
> 90 Royal Little Drive, Providence, RI 02904
> www.guardent.com
> _____________________________________________________
> G U A R D E N T
> Security | Privacy | Data Protection
>
>
> _______________________________________________________________________
> You are subscribed to the GroupStudy.com CCIE R&S Discussion Group.
>
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html