Re: Line Protocol down

From: Jay Hennigan (jay@west.net)
Date: Thu Jun 19 2003 - 19:34:57 GMT-3


On Thu, 19 Jun 2003, Yuki Hisano wrote:

> Group,
>
> I am having a trouble with this!!connection. R1------------R2 simple
> serial connection with HDLC.
> This connection is bouncing for no reason as far as I can tell. The status of
> the interfaces are
> Interface UP and Line Protocol DOWN. Line Protocol is going UP and DOWN
> causing this to be bouncing.
> I checked DSUs and the circuit is clean. There is no traffic coming in and out
> both ways.
> This happened before and I never figured why.
>
> Anybody has any idea?

Is one CSU set for internal clock, and the other set for line (or network)
clock? It should be. It doesn't matter which one, but one should be
internal and the other line.

-- 
Jay Hennigan - CCIE #7880 - Network Administration - jay@west.net
WestNet:  Connecting you to the planet.  805 884-6323      WB6RDV
NetLojix Communications, Inc.  -  http://www.netlojix.com/


This archive was generated by hypermail 2.1.4 : Fri Jul 04 2003 - 11:11:01 GMT-3