Re: Multilink

From: Glenn Goldie (ggoldie2@lineone.net)
Date: Thu Apr 10 2003 - 05:42:08 GMT-3


I'm pretty sure it is possible,

I thought when you type just dialer-load threshold command to bind two B
channels into one logical channel you are using cisco proprietary
Bandwidth On Demand. With ppp multilink command then it changes to using
PPP Multilink specifications (which should mean compatibility with
non-cisco vendor equipment).

I got this from the CCNP Remote Access Exam Cert Guide, Pg 153.

Rgds,
Glenn.

Hunt Lee wrote:

>Hi Tom,
>
>Don't think that is possible.
>
>Regards,
>Hunt
>
>
>-----Original Message-----
>From: Tom Young [mailto:gitsyoung@yahoo.co.jp]
>Sent: Thursday, 10 April 2003 2:39 PM
>To: ccielab@groupstudy.com
>Subject: Multilink
>
>
>Hi, group,
>
> Does it possible to use the dialer load-threshold
>command withOUT the ppp multilink command?
>
>Thanks alot
>
>__________________________________________________
>Do You Yahoo!?
>Yahoo! BB is Broadband by Yahoo! http://bb.yahoo.co.jp/