From: OhioHondo (ohiohondo@columbus.rr.com)
Date: Thu Mar 20 2003 - 21:22:28 GMT-3
If separate pvc's are used between 2 routers, one for data and one for
voice, is the FRTS configuration of the data pvc's Tc (and therfor Bc)
affected by the fact that both pvc's are sharing the same interface?
--voice pvc--
RouterA ---- FR -------- RouterB
-- data pvc--
(CIR = CIR contracted with provider)
Assume a CIR of 64K for each pvc and a Signaling Rate of 128K
for the voice pvc CIR=cir=mincir=64000
Bc= CIR/100= 640
Tc= CIR/Bc= 100
no adaptive shaping
for the data pvc CIR= 32K
mincir= 32000
cir= 64000
Bc= CIR/8 = 8000 -------------> are these
Tc= 8 (the default and CIR/Bc)-> correct??
adaptive-shaping becn
fragment size 80
This archive was generated by hypermail 2.1.4 : Sat Apr 05 2003 - 08:51:43 GMT-3