RE: Serial undead?

From: Brian Dennis (brian@5g.net)
Date: Tue Dec 24 2002 - 00:20:38 GMT-3


Yes, see below.

Labforge-AS#sho run int s1
Building configuration...

Current configuration:
!
interface Serial1
 no ip address
 no ip directed-broadcast
 no ip route-cache
 no ip mroute-cache
 no keepalive
 dialer in-band
 pulse-time 1
end

Labforge-AS#sho ip int brie s1
Interface IP-Address OK? Method Status
Protoco
Serial1 unassigned YES unset up up
Labforge-AS#sho cont serial 1
HD unit 1, idb = 0xBA4A4, driver structure at 0xBF938
buffer size 1524 HD unit 1, No cable
cpb = 0x62, eda = 0x3140, cda = 0x3000
<snip>
Labforge-AS#

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Jennifer Bellucci
Sent: Monday, December 23, 2002 6:23 PM
To: ccielab@groupstudy.com
Subject: Serial undead?

Hi all,

Can someone tell me how to make a serial interface come up with no cable
attached?
I have tried no keep, loopback, down-when-looped...any suggestions?
Is it even possible?

Thanks

Jennifer Bellucci

Jennifer_bellucci@hotmail.com
.
.



This archive was generated by hypermail 2.1.4 : Fri Jan 17 2003 - 17:21:52 GMT-3